![]() Introduction to Reference Display Profiling.If only low luminance level measurements are inconsistent or to increase the accuracy of low luminance measurements, you can increase the number of i1Pro measurement samples that CalMAN averages together.Tutorials / Introduction to Reference Display Profiling / Custom Offsets with the i1 Display Pro OEM in Lightspace DPS Series If all CalMAN measurements are inconsistent, you may want to try switching the i1Pro Sync Mode to “Off.” Select the Meter Mode that corresponds to the backlight or pixel technology of the display you wish to measure or calibrate. Placing the i1Pro on its baseplate accomplishes this.ĬalMAN Meter Settings Options Meter Modes (Target Display Types) The i1Pro initialization is a dark level calibration that depends on blocking light from entering the light aperture. This is indicated by a timer icon on the Meter Settings tab that indicates the minutes remaining before meter initialization is required.Ĭlick on the timer icon to open the meter initialize screen and follow the prompts. Leave Meter Search Options set to its default selection.Įach time you start CalMAN, and after 10 minutes of use, you will need to initialize the i1Pro.On the CalMAN Meter Settings page, click Find Meter.To switch CalMAN to using “Lux” measurement units while using the ambient filter, go to Settings > Application Preferences > Measurement Units. Use the filter when measuring ambient light or for measuring directly from a projector. To install the ambient filter on your i1Pro, snap the cap on the meter head, rotate slightly, and pull the cap directly off. Note that there are actually two pieces inside the black box the filter and a cap. Slide the two prongs on the tripod holder into the two holes on the bottom of the i1Pro, and wrap the attached Velcro strap around the i1Pro to secure it.Ī small black box is supplied with the i1Pro that contains the meter’s matched ambient filter (diffuser). You can also use the base plate to initialize the i1Pro each time you start using it with CalMAN.Ī suspension strap is supplied for hanging an i1Pro on a display.įor most applications, we instead recommend the tripod holder. Should you ever need to run the i1Pro diagnostics, it will expect the same reference tile. The i1Pro was calibrated at the factory to this reference material. At the tip of the base plate is a white tile of standard reference material. If the i1Pro does not function properly, try another USB port or a powered USB hub.Įach i1Pro is uniquely paired with its own numbered calibration base plate. IMPORTANT: Before trying to use a USB hub or extension cable, first verify proper operation with your i1Pro connected directly to your computer USB port. This may result in no operation or unpredictable i1Pro operation. Unpowered USB hubs and some USB ports do not supply enough current, and some USB extension cables may limit the current. The i1Pro is a USB 1.1 high power device that draws a substantial amount of current from a USB port (500ma 5V). To install the driver, go to Start/Control Panel, select System and then select Device Manager on the left-hand side of the System Properties window. Note: Windows 7 does not prompt for driver installation when a device is first attached. ![]() Windows 32-bit: C:/Program Files(x86)/Spectracal/Drivers/i1Pro.Windows 64-bit: C:/Program Files/Spectracal/Drivers/i1Pro.The typical i1Pro driver location will be:.To the prompt "What do you want the Wizard to do," select the option, "Install from a list or specific location." Use the Browse button to locate the directory where you installed the Device Driver Kit, then select the i1Pro directory. When you plug in your i1Pro, Windows will pop up a Found New Hardware wizard.Install the i1Pro and i1Pro 2 driver from the Calman Driver Pack The device driver will be installed as part of this installation, but be aware i1Profiler cannot be active when using Calman with the i1Pro meter.Download the i1Profiler package from this link.If you have installed the i1Profiler software, you will need to uninstall it before connecting CalMAN to the i1Pro. Important: CalMAN does not require the installation of any X-Rite software The X-Rite i1Profiler software captures the meter (X-Rite services) and prevents other software from connecting to the meter. X-Rite i1Pro driver, available for download here.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |